APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19
APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19
APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19
APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19
APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19

APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19

mpn: AP7954
product brand: APC
product condition: Used
excluding vat: £104.50
including vat: £125.40
information
APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19
P/N: AP7954
In Good Condition, Full Working Order
Tested
1 Year Warranty
Tested And Reset To Factory Default
Included
  • 1 x APC AP7954 Rack ZeroU Switched PDU Power Distribution Unit 16A 230V 21xC13 3xC19
AP7954 Features
Rack PDU, Switched, Zero U,16A,230V,(21)C13&(3)C19, IEC309
Switched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.
Switched Rack PDU Features & Benefits
Marketing Features
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by provided a visible warning when the current draw is close to the maximum amperage draw of the strip.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependent on that unit will function properly.
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Adaptability
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Manageability
Multi-tier user access
Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Network port sharing
Allows four rack PDUs to be connected using In and Out ports so that only one network connection is necessary.
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.
Manufacturer's Specifications
Output
  • Nominal Output Voltage: 230V
  • Maximum Total Current Draw: 16
  • Output Connections
  • (21) IEC 320 C13 (Battery Backup)
  • (3) IEC 320 C19 (Battery Backup)
Input
  • Nominal Input Voltage: 200V, 208V, 230V
  • Input frequency: 47 - 63 Hz
  • Input Connections: IEC 309 16A 2P+E
  • Cord Length: 3.05meters
  • Acceptable Input Voltage: 220-240VAC
  • Number of Power Cords: 1
  • Load Capacity: 3680VA
  • Maximum Input Current: 16A
Physical
  • Maximum Height: 1619mm, 161.9CM
  • Maximum Width: 56mm, 5.6CM
  • Maximum Depth: 44mm, 4.4CM
  • Net Weight: 5.92KG
  • Color: Black
Environmental
  • Operating Temperature: -5 - 45 °C
  • Operating Relative Humidity: 5 - 95 %
  • Operating Elevation: 0-3000meters
  • Storage Temperature: -25 - 65 °C
  • Storage Relative Humidity: 5 - 95 %
  • Storage Elevation: 0-15000meters
 
SA 291185
specifications
  • MPN:
    AP7954

to request a price please fill out the form below...


close