Harland Protect UPS-M-PX 11kVA 10kW Marine Ship 1 Phase UPS Power + Cabinet 240V
Model: Protect UPS-M-PX
P/N: 9PX11KiPM
P/N: SC240RT
New
Built for a showroom display - never been used
Not Supplied With Batteries
Included
- 1 x Harland Protect UPS-M-PX 11kVA 10kW 3 Phase UPS/Battery Cabinet NO BATTERIES
- 1 x Eaton 9PX 11kVA 10kW RackMount UPS - 9PX11KiPM
- 1 x Eaton UPS Battery Supercharger Module - SC240RT
- 1 x Battery Tray On Runners (for easy maintenance)
- 1 x Integrated Maintenance Bypass Switch
- 1 x Auto Input Changeover
- 1 x Output Distribution
- 2 x IP54 Air Filters
Protect UPS M-PX Cabinet
Specification
Output Rating @ 40°C: Max 11 kVA/10 kW
Output Rating @ 45°C: Max 6.1kVA/4.25kW
UPS Module: Eaton 9PX range on-line double conversion with integral static bypass
Battery Autonomy: 5 - 6 minutes (normally 30 minutes)
System IP Rating: IP20 - IP54 (normally IP54)
Enclosure: 2mm welded steel rugged construction with base mounted cable entry gland plate; Fitted with fixing assembly, lifting eyes and AVM's
Finish: Standard colour RAL7035 (other colours available upon request)
Dimension(H x W x D): 1700mm x 600mm x 850mm
Weight: 600kg
Output Rating @ 45°C: Max 6.1kVA/4.25kW
UPS Module: Eaton 9PX range on-line double conversion with integral static bypass
Battery Autonomy: 5 - 6 minutes (normally 30 minutes)
System IP Rating: IP20 - IP54 (normally IP54)
Enclosure: 2mm welded steel rugged construction with base mounted cable entry gland plate; Fitted with fixing assembly, lifting eyes and AVM's
Finish: Standard colour RAL7035 (other colours available upon request)
Dimension(H x W x D): 1700mm x 600mm x 850mm
Weight: 600kg
Eaton 9PX 5-11kVA 10kW RackMount UPS - 9PX11KiPM
Specification
General
- Topology: On-line double conversion with PFC (Power Factor Correction) system
- Configuration: Rack/Tower
- Part Number: 9PX11KiPM and 9PXEBM240
- Rating (VA/Watts): 11000/10000
- Dimensions (H x W x D, mm): 260 (6U) x 440 x 685
- Weight (kg): 86
Electrical Input
Connection
- Input Voltage Range: 176-276V without derating (up to 100-276V with derating)
- Nominal Voltage: 200/208/220/230/240/250V
- Frequency: 50/60 Hz autoselection
- Frequency Range: 40-70 Hz
- Short Circuit Current: 150 A
- THDI: <5%
Electrical Output
- Voltages: 200/208/220/230/240/250V +/- 1%
- Voltage THD: < 2%
- Overload Capacity: 102-110% : 120s, 110-125%: 60s, 125-150%: 10s, >150%: 900ms
- Efficiency (Normal Mode): Up to 95% in Online mode, 98% in Hi-Efficiency mode
- Output Frequency: 50/60 Hz autoselect, frequency converter as standard
- Load Crest Factor: 3:1
Battery
- Battery Management: ABM and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units.
- Extended Battery Capability: EBM (3U)
Communications
- User Interface: Multilingual graphical LCD display
- Communication Ports: 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 mini terminal block for remote On/Off and 1 for remote power Off, 1 DB15 for parallel operation.
- Communication Slot: 1 slot for Network-MS card, ModBus-MS or Relay-MS cards
Environmental & Standards
- Audible Noise: <50dB
- Operating Temperature: 0 to 40°C continuous
- Safety markings: IEC/EN 62040-1, UL 1778, CSA 22.2
- EMC Markings: IEC/EN 62040 -2 , FCC Class A, IEC/EN 62040-3 (Performance), C-Tick
- Approvals: CE, CB report (TUV), UL (Power Module)
Eaton UPS Battery Supercharger Module - SC240RT
Specification
Weight & dimensions
- Width: 439.4 mm
- Depth: 680.7 mm
- Height: 129.5 mm
- Weight: 15422 g
Certificates
- Certification: CE, cULus, NOM
Performance