information
IBM 53959KX 81Y2321 11kVa 11000VA 10KW Rack Mount 230V 1Ph UPS +Extended Runtime
In Good Condition And Full Working Order
Batteries Installed
Full Load 14min & Half Load 35min Runtime
Included:-
1 x IBM 5395-9KX 11000VA 10000w LCD 5U Rack UPS (208V/230V)
1 x IBM 69Y1986 11000VA UPS 3U Extended Battery Module (EBM)
1 x Eaton Lenovo IBM UPS Network Management Card 00W0C523 710-U0086-04P
1 x Set Rack Mount Rails
Specification
IBM 11000VA LCD 5U Rack UPS (208V/230V)
IBM part number 5395-9KX
VA/Watts rating 11000 VA/10000 W
Nominal output voltage (Vac) 208 V/230 V auto sensing at first powerup, userconfigurable
Rated power output 11000 VA (normal and high efficiency modes)5500 VA (double conversion mode)
Output power capacity in watts 10000 W (normal and high efficiency modes)5000 W (double conversion mode)
Load segments Two
Output connections Eight IEC 320 C19
Circuit breakers Four two-pole output breakers rated at 20 A (two breakersfor each load segment)
Efficiency Normal mode: 93%High efficiency mode: 96%Battery mode: 90%
Input
Nominal input voltage 208 V/230 V (auto sensing at first powerup)
Maximum input current 69.96 A (line mode)58.33 A (battery mode)
Input frequency (auto sensing) 50/60 Hz +/- 3 Hz
Input connection type Hardwired to terminal block
Included line (input) cords None
Input voltage range, mains operations 155-255 V for 208 V
Batteries
Battery type Valve Regulated Lead Acid (VRLA): maintenance-free,sealed, leak-proof
External Battery Pack 69Y1986
Typical recharge time 3 hours to 90% charge from a UPS/battery discharge of50% rated load
Communications and management
USB port Yes
RS-232 serial port Yes
Ethernet port Optional using Network Management Card, 46M4110Environmental Monitoring Probe Optional
Environmental Monitoring Probe, 46M4113
Surge protection and filtering
Surge energy rating 1300 Joules
Filtering ANSI/IEEE C62.41; 1991 CATEGORYB3 (SURGE)
Physical specifications and operating environment
The physical specifications of the 5U uninterruptible power supply are as follows:
Height: 212 mm (8.3 in.)
Width: 483 mm (19 in.)
Depth: 740 mm (29.1 in.)
Weight: 99 kg (218 lb)
The physical specifications of the 3U Extended Battery Module are as follows:
Height: 127 mm (5.0 in)
Width: 483 mm (19 in.)
Depth: 740 mm (29.1 in.)
Weight: 79 kg (174 lb)
The IBM 11000VA LCD 5U Rack UPS is supported in the following operating environment:
Temperature: 0 - 40.0° C (32 - 104° F) at 0 - 2,000 m (0 - 6,600 ft)
Relative humidity: 5 - 95%
Maximum altitude: 3,048 m (10,000 ft)
VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE OF THE UK
SL
specifications
-
MPN:5395-9KX
to request a price please fill out the form below...